noise barrier railway
Yukings · noise barrier & sound barrier manufacturer Since 2006

Angled, folded & cantilever cap noise barriers — L-cap cantilever profile that creates an extended acoustic shadow zone behind the barrier, delivering the highest effective insertion loss per meter height.

Yukings angled-top (also called folded-top, cantilever-cap or L-cap) noise barriers add a horizontal or downward-angled cantilever cap at the top of the wall, creating an extended acoustic shadow zone behind the barrier and delivering the highest effective insertion loss per meter of barrier height available in conventional noise wall design. Cantilever caps are particularly effective for high-speed railway noise and for residential buildings close to the road.

L-Cap Cantilever ProfileExtended Acoustic Shadow ZoneHighest Insertion Loss per HeightHSR Noise EffectiveResidential-Friendly
30-45 dBinsertion loss
120-200 mmpanel depth
2.0-2.5 mbays
25 yrdesign life
Product Overview

Angled / Folded-Top Noise Barriers — L-Cap Cantilever Profile

The L-shaped cantilever cap creates an extended acoustic shadow zone behind the wall, delivering the highest effective insertion loss per meter of barrier height available in conventional noise wall design. Cap projection typically ranges from 300 mm to 800 mm horizontal distance and can be tuned to match your receiver geometry, site constraints and required attenuation target.

noise barrier
What is it

L-cap cantilever profile for maximum insertion loss per meter height.

Yukings folded-top / L-cap barriers combine a standard vertical absorption panel column with a galvanized steel or aluminum alloy cantilever cap projecting horizontally or at a downward angle into the receiver side. The cap creates an extended acoustic shadow zone — effectively shielding receptors behind the wall from both direct line-of-sight and diffracted sound rays — delivering the highest effective insertion loss per meter of barrier height of any conventional noise wall profile.

  • High-speed rail corridors, urban metro and light-rail lines
  • Residential buildings located close to highways and roads
  • Schools, hospitals and other community-sensitive receptors
  • Cap projection 300-800 mm horizontal; fully tunable per project
  • 120/140/160/200 mm absorptive panel depths with EPDM membrane
Technical Specification

Angled / Folded-Top Noise Barriers — Full Specification

Detailed engineering specification for Yukings angled / folded / cantilever cap L-top noise barriers. Cap projection, angle and depth are fully project-tunable.

Angled / Folded / Cantilever Cap Noise Barriers — Product Specification

L-shaped cantilever cap design with project-tunable cap projection for maximum insertion loss per meter of barrier height.

PropertyValue
Insertion Loss DL (EN 1793-3)30 – 45 dB (including cap diffraction gain)
Sound Insulation Rw (EN ISO 717-1)38 – 55 dB
Top ProfileL-shaped angled / folded cantilever cap
Cap Projection300 – 800 mm horizontal projection (project-tunable)
Cap Materialgalvanized steel / aluminum alloy
Panel MaterialDX51D+Z galvanized steel 1.5-3.0 mm with absorptive core
Panel Depth120 / 140 / 160 / 200 mm
Absorptive Corerock-wool 100-140 kg/m3 with EPDM membrane
H-post Column SizeH 125 x 125 x 6.5 x 9 to H 200 x 200 x 9 x 14
H-post Spacing2.0 m or 2.5 m bays
Barrier Height (incl. cap)3.0 – 8.0 m including cantilever cap
Transparent Window8 / 10 / 12 mm polycarbonate compatible
Finishhot-dip galvanized + RAL powder coat
Corrosion ResistanceISO 12944 C3-M / C4-H
Fire RatingClass A (EN 13501-1)
Wind / Cap Momentdesigned for cantilever loads per project
Design Service Life25 years
Structural Warranty15 years
Why Yukings

What makes our Angled / Folded-Top Noise Barriers different

From acoustic shadow-zone simulation through cap-moment structural engineering and containerized shipping, Yukings delivers L-cap cantilever barriers tailored to your project geometry and attenuation requirements.

A1

Highest Insertion Loss per Meter

The L-shaped cantilever cap delivers the highest effective insertion loss per meter of barrier height available in conventional noise wall design — verified by project-specific acoustic simulation.

A2

Extended Acoustic Shadow Zone

Horizontal or downward-angled cap projection creates an extended acoustic shadow zone behind the wall, effectively shielding receptors from both direct and diffracted sound paths.

A3

300-800 mm Project-Tunable Cap

Cap projection from 300 mm to 800 mm horizontal distance, fully tunable per project based on receiver height, source height, barrier distance and required attenuation target.

A4

Cap Moment Structural Engineering

Cantilever cap moment, H-post column size (H 125x125x6.5x9 to H 200x200x9x14), wind load and foundation load are all calculated per project for structural safety.

A5

30-45 dB Insertion Loss

Full EN 1793 / EN 1794 test dossier with CE marking; project-specific diffraction gain and shadow-zone simulation report delivered with every tender.

A6

HSR and Residential Friendly

Ideal for high-speed rail corridors and residential buildings close to roads and railways, where maximum attenuation per meter of barrier height is critical to meet noise compliance.

A7

120-200 mm Absorptive Panels

Deep absorptive panel depths (120/140/160/200 mm) with 100-140 kg/m3 rock-wool core and EPDM waterproof membrane for long-term broadband absorption performance.

A8

ISO 12944 C3-M / C4-H Corrosion

Hot-dip galvanized plus RAL powder-coat finish with C3-M or C4-H corrosion classification for long service life near coastal areas and heavy industrial environments.

Related Products & Use Cases

Other noise barrier profiles and solutions

Compare angled-top / L-cap barriers with Yukings flat-top and curved-cap profiles, or explore our dedicated application-specific noise wall product lines.

noise barrier highway
Flat Top
Product

Flat / Straight Top Noise Barriers

Classic straight-profile noise wall with standard modular panel construction; default specification for cost-effective high-volume highway and railway projects.

View Product →
noise barrier highway
Curved Top
Product

Curved / Arc Top Noise Barriers

Engineered curved-cap profile redirects diffracted sound waves over the barrier top, delivering +3-8 dB additional attenuation compared to equivalent-height flat-top walls.

View Product →
noise barrier highway
Highway
Use Case

Highway & Road Noise Barriers

Metal-louvered absorption panels with optional polycarbonate or concrete sections for expressway, ring road and bridge parapet noise control.

View Product →
noise barrier railway
Railway
Use Case

Railway Noise Barriers

Rigid modular panels designed for high-speed rail aerodynamic load, cantilever-cap moment, vibration, fatigue and slip-stream requirements.

View Product →
noise barrier residential
Residential
Use Case

Residential Community Noise Barriers

Cantilever cap and curved-profile barriers for housing developments, schools, hospitals and sensitive residential reception areas close to roads and railways.

View Product →
noise barrier industrial factory
Industrial
Use Case

Industrial Plant Noise Barriers

Absorptive metal-faced panels with Class A fire rating for power plants, factories, warehouses, compressor stations and industrial perimeter walls.

View Product →
Frequently Asked

Angled / Folded-Top Noise Barriers — FAQs

Commonly asked technical, commercial and logistics questions about Yukings angled / folded / L-cap cantilever-top noise barriers.

How does the L-shaped cantilever cap deliver higher insertion loss than a flat or curved top?
The cantilever cap physically extends the barrier top horizontally or at a downward angle toward the receiver side, creating an extended acoustic shadow zone. This configuration interferes with both direct line-of-sight and top-edge diffraction, delivering the highest effective insertion loss per meter of barrier height of any conventional noise wall profile. Compared with a flat-top wall of equivalent height, the L-cap design can provide 5-15 dB of additional effective attenuation at typical receptor locations.
What cap projections are available, and how do you size them for our project?
Standard cap projections range from 300 mm to 800 mm horizontal distance. Yukings provides project-specific acoustic simulation to determine the optimal cap projection, angle and barrier height for your receiver geometry, source characteristics and noise compliance target. Cap dimensions are fully tunable within this range to meet your design requirements.
What structural considerations are specific to cantilever cap barriers?
Cantilever-cap barriers generate significant cap moment at the top of the H-post column, requiring heavier column sections (H 125x125x6.5x9 to H 200x200x9x14) compared with flat-top or curved-top designs. Yukings calculates cap-moment, wind load, foundation reaction, fatigue and slip-stream loads as part of every project, with full structural calculation drawings delivered for your approval.
What are the typical panel depths and infill materials for L-cap barriers?
Yukings angled-top barriers use standard 120/140/160/200 mm deep absorptive panels with DX51D+Z galvanized steel face sheets (1.5-3.0 mm) and 100-140 kg/m3 rock-wool absorptive core protected by an EPDM waterproof membrane. Transparent window sections in 8/10/12 mm UV-stabilized polycarbonate are fully compatible and can be integrated at any vertical position in the panel column.
What test certificates and documentation do you provide for tenders?
Yukings provides EN 1793 insertion loss, EN 1794 airborne sound insulation, EN ISO 717-1 Rw, EN 13501-1 fire rating, ISO 12944 C3-M / C4-H corrosion classification, EN 1991-1-4 wind load calculation, full CE marking documentation, project-specific acoustic simulation, shadow-zone report and cap-moment structural calculation with every cantilever-cap noise barrier project.
Ready to Take the Next Step?

Need an Angled / Folded / Cantilever Cap Noise Barriers quotation for your project? Contact Yukings today.

Our L-cap cantilever noise barrier specialists will respond to your project inquiry within 24 hours, including acoustic simulation guidance and structural recommendations where applicable.

Tel+86-755-86366707
Emailweilai04525@163.com
Miss Tang (Sales)+86 17727812004
Mr. Yu (Engineering)+86 13828819804
Project Inquiry

Tell us about your angled-top noise barrier project

Share your project parameters and a Yukings engineer will prepare a tailored proposal, including cap projection, acoustic simulation and structural recommendations.

Project Quote Request — Angled / Folded / Cantilever Cap Noise Barriers

Fields marked * are required. We respond within 24 hours Beijing time.